~BRSMDF
~BRSMDF, ICSEC, Lab1, Lab2, Lab3, VALUE, IDX1, IDX2, IDX3
Modifies bridge cross-sections data
PREP7 : BRIDGE AND CIVIL NON LINEARITIES: Bridge model generation
ICSEC
Cross section number to modify.
Lab1, Lab2, Lab3
Indicate the property to define or modify in the cross section. The valid label and the fields used are shown hereafter (if properties are not indicated, they will be left blank).
VALUE
Assigned value to the specified property in Lab1, Lab2 and Lab3.
IDX1, IDX2, IDX3
Identifying index of the property to modify. Valid values depend on the different group properties defined in Lab1, Lab2 and Lab3.
|
Lab1 |
Lab2 |
Lab3 |
Description |
||||||
|
NAME |
|
|
VALUE = name of the section. |
||||||
|
MAT |
|
|
VALUE = section material |
||||||
|
BOX |
|
|
It modifies data of box sections. |
||||||
|
|
KSYM |
|
VALUE = 0, 1, -1
|
||||||
|
|
CELL |
|
IDX1 = cell number (0 = ALL). |
||||||
|
|
|
WIDTH |
VALUE = cell width. |
||||||
|
|
|
THTOP |
VALUE = top thickness (slab). |
||||||
|
|
|
THBOT |
VALUE = bottom thickness. |
||||||
|
|
WEB |
|
IDX1 = web number (0 = ALL). |
||||||
|
|
|
DEPTH |
VALUE = web depth (distance between directrix). |
||||||
|
|
|
THICK |
VALUE = web thickness. |
||||||
|
|
|
SLOPE |
VALUE = web slope respect to the vertical. Positive in counter-clockwise direction. |
||||||
|
|
|
RATS |
VALUE = flange length ratio corresponding to the slope starting point. IDX2= IT, the IT field is referred to the corners (see values in SLPB). |
||||||
|
|
|
SLPS |
VALUE = slope respect to the corresponding directrix (always positive). IDX2= IT, the IT field is referred to the corners (see values in SLPB). |
||||||
|
|
|
RATB |
VALUE = corresponding flange length ratio where the bracket starts. IDX2= IT, the IT field is referred to the corners (see values in SLPB). |
||||||
|
|
|
SLPB |
VALUE
= bracket slope respect to the corresponding
directrix (always positive) IT=0:
all the corners. |
||||||
|
|
FLANGE |
|
VALUE = flange number (0 = ALL). |
||||||
|
|
|
LENGTH |
VALUE = flange length (0 to clear the flange). |
||||||
|
|
|
THICK |
VALUE = flange thickness. |
||||||
|
|
CROWN |
|
Crown. |
||||||
|
|
|
THINCR |
VALUE = additional slab thickness. |
||||||
|
|
|
RATIO |
VALUE = distance ratio of the bridge deck where the thickness is applied (by default 0.5). |
||||||
|
|
RMAT |
|
VALUE = Reinforcement material. |
||||||
|
|
MC |
|
VALUE = Mechanical cover for the reinforcement. |
Menu Paths
Main Menu > CIVIL Preprocessor > Bridges Prep > Bridge Sections > Modify