Left

CivilFEM Online Help

Right

~/SBSHOW

 

~/SBSHOW, Label, ID, VALUE1, VALUE2, VALUE3, …, VALUE23

Changes the visualization properties of the tendon editor

PREP7: PRESTRESSED CONCRETE: Support beam

Label

Group of properties that will be modified

Label

Description

GLOBAL

Global properties.

CUT

Properties of a cut of the support beam.

TENDON

Properties of a tendon.

ALLTND

Properties of the group of all tendons.

 

ID

Number of the entity which will be modified.

VALUE1 to VALUE23

Values for each of the properties. It depends on the value of Label.
If any of the values are left blank, it will not be modified.

Label = GLOBAL, ID not used.

VALUE

Description

1

Cut numbers in the data table:

0

Not shown

1

Shown as text

2

Distance to each cut in the data table:

0

Not shown

1

Shown as text

3

Upper cover at each cut:

0

Not shown

1

Shown as text

4

Lower cover at each cut:

0

Not shown

1

Shown as text

5

Associated node to each cut for beam models:

0

Not shown

1

Shown as text

6

Relative font size percentage (by default 100)

7

Data table Height/Width percentage.

8

Data table graph Height/Width percentage.

9

Data table graph:

0

Not shown

2

Shown

10 to 23

Not used.

 

Label = CUT, ID = Number of the cut (If 0 or blank, the properties will be changed in all tendons).

VALUE

Description

1

Cut in the data table:

0

Not shown

1

Shown

2

Text angle, measured in degrees from the horizontal, anticlockwise.

3 to 23

Not used.

 

Label = TENDON, ID = Number of the tendon (If 0 or blank, the properties will be changed in all tendons).

VALUE

Description

1

Tendon in the data table:

0

Not shown

1

Shown

2

Slippage of strands losses discontinuities:

2

Show on graph

3

Show in the data table and on the graph

3

Y coordinate:

0

Not shown

1

Shown in the data table

4

XY slope:

0

Not shown

1

Shown in the data table

5

Z coordinate:

0

Not shown

1

Shown in the data table

6

XZ slope:

0

Not shown

1

Shown in the data table

7

Points numbers in plan view:

0

Not shown

1

Shown in the data table

8

Points numbers in elevation view:

0

Not shown

1

Shown in the data table

9

Steel relaxation losses before transfer and due to heating (pre-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

10

Thermal expansion losses (pre-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

11

Friction losses (post-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

12

Slippage of strands in the anchorages losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

13

Elastic shortening of concrete member losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

14

Concrete shrinkage losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

15

Concrete creep losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

16

Steel relaxation losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

17

Immediate losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

18

Long-term losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

19

All losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

20

Initial tendon force:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

21

Anchorage tendon force:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

22

Initial tendon stress:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

23

Anchorage tendon stress:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

 

Label = ALLTND, ID = Not used.

VALUE

Description

1

All tendons group:

0

Not shown

1

Shown

2 to 8

Not used.

9

Steel relaxation losses before transfer and due to heating (pre-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

10

Thermal expansion losses (pre-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

11

Friction losses (post-tensioned only):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

12

Slippage of strands in the anchorages losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

13

Elastic shortening of concrete member losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

14

Concrete shrinkage losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

15

Concrete creep losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

16

Steel relaxation losses:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

17

Immediate losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

18

Long-term losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

19

All losses (added):

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

20

Initial tendon force:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

21

Anchorage tendon force:

0

Not shown

1

Shown in the data table

2

Show on the graph

3

Show in the data table and on the graph

22 to 23

Not used.

 

Notes

- The support beam must be defined.

Menu Paths

Main Menu > Civil Preprocessor > Prestress Concrete Prep > Tendons > Tendon Editor

¾¾¾¾¾¾¨¾¾¾¾¾¾